-20%

PRISM12X12

Symetrix 12X12 Dsp Processor

SKU PRISM12X12 Categories ,

Share:

SYMETRIX This 12×12 analog I/O version, with 64×64 Dante and the exact same powerful Symetrix DSP engine found in our Edge and Radius products.Incredible Sound. Industry leading analog mic-pre and A/D/D/A performance, 48 volt phantom mic power. Control made easy. Multiple control options include zero cost ARC-WEB browser interface, low-cost Symetrix ARC wall panels, easy to generate SymVue Windows GUI. A stable, human readable protocol is used to program third-party touch screens.

Analog Inputs
– Number of Inputs: Twelve 12 switchable balanced mic or line level.
– Connectors: 3.81 mm terminal blocks.
– Nominal Input Level: +4 dBu.
– Maximum Input Level: +23 dBu.
– Mic Pre-amp gain: 0, 12, 24, 44 or 54 dB switchable with ± 24 dB trim.
– Mic Pre-amp EIN: -125dB with 150 ohm source impedance. 22.4 kHz BW.
– CMRR: 79 dB @ 1 kHz, unity gain.
– Input impedance: 8k Ohms balanced, 4k Ohms unbalanced.
– Phantom power per input: +48 VDC, 10 mA maximum.
– Dynamic range: 113 dB, A-weighted.
– THD+Noise: -100 dB 22.4 kHz BW, unweighted 1 kHz @ +15 dBu with 0 dB gain. Course gain is set to +4dBu.
– A to D Latency: 0.28 mS.

Mechanical Specifications
– Space Required: 1U WDH: 18.91 in. x 9.5 in. x 1.72 in. / 48.02 cm x 24.13 cm x 4.37 cm. Depth does not include connector allowance. Allow at least 3 inch additional clearance for rear panel connections. Additional depth may be required depending upon your specific wiring and connections.
– Electrical: 24V 1.9A, 45W Maximum. Symetrix Part Number 12-0034. CUI part number SDI65-24-U-P5.
– Ventilation: Maximum recommended ambient operating temperature is 30 C / 86 F. Ensure that the left and right equipment sides are unobstructed 5.08 cm, 2 in minimum clearance. The ventilation should not be impeded by covering the ventilation openings with items such as newspapers, tablecloths, curtains, etc.
– Certifications or Compliance: Safety: UL 60065, cUL 60065, IEC 60065. EMC: “Class A” device applies to all of the following EN 55032, EN 55103-2, EN 61000-3-2, EN 61000-3-3, FCC Part 15, ICES-003. Environmental: RoHS.
– Shipping Weight: 9 lbs. 4.1 kg

Analog Outputs
– Number of Outputs: Twelve 12 balanced line level.
– Connectors: 3.81 mm terminal blocks.
– Nominal Output Level: +4 dBu with 20 dB of headroom.
– Maximum Output Level: +24 dBu +22.8 dBu into a 2k Ohm minimum load.
– Output Impedance: 300 Ohms balanced, 150 Ohms unbalanced.
– Dynamic Range: 117 dB, A-weighted.
– THD+Noise: -97 dB 22.4 kHz BW, unweighted 1 kHz, 0 dB gain +8dBu output.
– D to A Latency: 0.60 mS.
System
– Sampling Rate: 48 kHz.
– Frequency Response A/D/A: 20 Hz – 20 kHz, ± 0.5 dB.
– Dynamic Range A/D/A: 113 dB, A-weighted.
– Channel Separation A/D/A: 110 dB @ 1 kHz, +24 dBu.
– THD+Noise: -95 dB 22.4 kHz BW, un-weighted 1 kHz @ +15 dBu with 0 dB gain.
– Latency A/D/A: 1.04 mS, inputs routed to outputs.
– Processors: 1 x Analog Devices SHARC 21489 @ 400 MHz SIMD.
– Raw Processing Capacity: 400 MIPS, 1.6 GFLOPS.
– Delay Memory: 174 mono seconds.
– Analog control inputs: 0-3.3 VDC.
– Recommended External Control Potentiometer: 10k Ohm, linear.
– Logic Outputs: Low 0V when active, pulled high 5V when inactive.
– Logic Output Maximum External Power Supply Voltage: 24 VDC.
– Logic Output Maximum External Power Supply Current Sinking: 50 mA.
– Logic Output Maximum Output Current: 10 mA.
– RS-485 Serial I/O: 38.4 kbaud default 8 data bits, 1 stop bit, no parity, no flow control. May be broken out of ARC port.
– Ethernet Cable: Standard CAT5e or CAT6, maximum device-to-device length = 100 meters.
– Dante Cable: Standard CAT6, maximum device-to-device length = 100 meters.
– ARC Cable: Standard CAT5, distance dependent upon load and number of devices. 8 Watts maximum power available.
– Maximum Devices Per System: 80 units per Site File.
– Maximum Stored Presets: 1000.

PRISM12X12.pdf
Scroll to Top